Electrical Panel


LT Panels

  • Rated Current up to 6300.
  • A Fault Level up to 100 kA for 1Sec.
  • Construction of Panel – Form 3B/4A/4B.
  • Busbar – Aluminium or Copper.
  • Our PCC Panels are functionally color coded for easy identification of feeder.


HT Panels

  • Ratings: 3P. 3W, 50Hz, 12kV, 630A to 1600 A.
  • Fault Level – 25 kA for 3 Sec.
  • Busbar – Copper / Aluminium.
  • Dimensions : As per specification.
  • Simple & Compact design.
  • Earthed Metallic partitions & shutters.
  • Confirms to IS / IEC standards and is fully type tested.
  • Totally restrike free.
  • Suitable for Rapid auto-reclosing duty.
  • Highly Reliable operation.
  • Suitable for all environments.
  • High Switching Capacity.
  • All type tests carried out with VCB mounted inside the panel (Short Circuit Test / Impulse Test, IP Protection Test, Temp. Rise Test).


Control Panels

Automatic Control of Diesel Generator Sets incorporating following functions:-

  • AMF (Auto- Mains failure).
  • AS (Auto Synchronizing).
  • ALS (Auto Load Sharing).
  • LDSS (load Dependent start / Stop).
  • LS (Load shedding).
  • Common Control PLC Panel for up to 8 Diesel Generator Sets.
  • SCADA View terminal Points.
  • Manual Synchronizing of Diesel Generator Sets.
  • Protection & Control of Diesel Generator Sets through Multi Function relay.
  • Man Machine Interface (MMI).
  • Annunciation & fault indication.


Distribution Panels

  • Rated Current up to 3200 A.
  • Fault Level up to 50 kA for 1 Sec.
  • Construction of Panel – Form 3B/4A/4B.
  • Single Front / Double Front.


MCC Panels

  • Rated Current up to 4000 A.
  • Fault Level up to 65 kA for 1 Sec. Construction of Panel – Compartmentalized & Non – Compartmentalized.
  • Busbar – Aluminium or Copper.
  • Type of Starter – DOL Starter / R DOL & H DOL starters /Star Delta Starters / Soft Starters / VFD’s / Single Front / Double Front.


Synchronizing Panels

Automatic Control of Diesel Generator Sets incorporating following functions:-

  • AMF (Auto- Mains failure).
  • AS (Auto Synchronizing).
  • ALS (Auto Load Sharing).
  • LDSS (load Dependent start / Stop).
  • LS (Load shedding).
  • Common Control PLC Panel for up to 8 Diesel Generator Sets.
  • SCADA View terminal Points.
  • Manual Synchronizing of Diesel Generator Sets.
  • Protection & Control of Diesel Generator Sets through Multi Function relay.
  • Man Machine Interface (MMI).
  • Annunciation & fault indication.


AMF (Auto Mains Failure) Panels

This is a Module with Generator monitoring, protection and start facilities. Operation of the module is operated from the front panel with STOP, MANUAL and AUTO positions.

When the AC mains supply returns to within limits, the module will transfer load back to the mains. The engine will be instructed to stop after a cool-down period. The module’s microprocessor provides a comprehensive function.

AMF control System provides:-

  • Consistent Power Supply to the load.
  • Smooth Start / Stop Sequence.
  • Audio / Visual indication of various fault conditions.
  • Auto / Manual modes of operations.
  • Mains failure and voltage fluctuation detection.

AMF control System provides:-

  • Range from 7.5 KVA to 3000 KVA.
  • Logic Panels with normal source or with standby DG source.
  • Basic protection under / over voltage, under / over frequency.
  • Provision with future synchronising.
  • Metering (Voltage, Ammeter, Frequency, KWH) & Battery charger unit.
  • Modbus communication facility.
  • DG Breaker & mains Breaker (Optional).